Massbank MS database records for Inosine
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-Washington_State_Univ-BML81456 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | NEGATIVE | MS |
MSBNK-Washington_State_Univ-BML81458 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | NEGATIVE | MS |
MSBNK-Washington_State_Univ-BML81455 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | POSITIVE | MS |
MSBNK-RIKEN_NPDepo-NGA00097 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_NPDepo-NGA00098 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_NPDepo-NGA00099 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_NPDepo-NGA00100 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | [M+H]+ | POSITIVE | MS2 |
MSBNK-Antwerp_Univ-METOX_P101303_F638 | Agilent 6530 QTOF | LC-ESI-QTOF | 10 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Antwerp_Univ-METOX_P101303_EF88 | Agilent 6530 QTOF | LC-ESI-QTOF | 20 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Antwerp_Univ-METOX_P101302_FB57 | Agilent 6530 QTOF | LC-ESI-QTOF | 40 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Antwerp_Univ-METOX_P100536_9EE2 | Agilent 6530 QTOF | LC-ESI-QTOF | 10 eV | [M+Na]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO001170 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001171 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001172 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001173 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001174 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00580 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS |
MSBNK-NAIST-KNA00708 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS |
MSBNK-NAIST-KNA00581 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00582 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00709 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00710 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00177 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS |
MSBNK-NAIST-KNA00308 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS |
MSBNK-NAIST-KNA00179 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00309 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00311 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-Metabolon-MT000143 | LTQ XL, Thermo Finnigan | LC-ESI-IT | 40 | [M-H]- | NEGATIVE | MS2 |
MSBNK-BGC_Munich-RP011001 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 10 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP011002 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 20 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP011003 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 40 | [M+H]+ | POSITIVE | MS2 |
MSBNK-Osaka_Univ-OUF00281 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR010169 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR100571 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR100151 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100150 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |