MoNA MS database records for Mesaconic acid
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PT200930 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT207540 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PS009307 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS075407 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS075408 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PS009301 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS075401 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS009302 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS075402 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS009303 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS075403 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PR100510 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR100761 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
FiehnLib000116 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000117 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000118 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000119 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000120 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000289 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
KZ000059 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR010190 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00000578340 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
HMDB0000749_ms_ms_864 | Q-Exactive Plus | Quattro_QQQ | - | - | - | negative | MS2 |
HMDB0000749_ms_ms_865 | Q-Exactive Plus | Quattro_QQQ | - | - | - | negative | MS2 |
HMDB0000749_ms_ms_866 | Q-Exactive Plus | Quattro_QQQ | - | - | - | negative | MS2 |
HMDB0000749_ms_ms_1068 | Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | - |
HMDB0000749_ms_ms_1069 | Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | - |
HMDB0000749_ms_ms_1070 | Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | - |
HMDB0000749_c_ms_1065 | Q-Exactive Plus | GC-MS | - | - | - | - | - |
HMDB0000749_c_ms_1093 | Q-Exactive Plus | GC-MS | - | - | - | - | - |