Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MT000030 | LTQ XL, Thermo Finnigan | LC-ESI-IT | ESI | 40 | [M]+ | positive | MS2 |
PT110163 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | 30 V | [M]+ | positive | MS2 |
PT110160 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M]+ | positive | MS2 |
PS101601 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS101602 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS101603 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS101604 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PB001602 | TSQ 7000 | LC-ESI-QQ | ESI | 20 eV | [M]+ | positive | MS2 |
PB001603 | TSQ 7000 | LC-ESI-QQ | ESI | 25 eV | [M]+ | positive | MS2 |
PR100405 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 V | [M]+ | positive | MS2 |
PR100404 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M]+ | positive | MS2 |
MoNA010980 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M]+ | positive | - |
MoNA010981 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M]+ | positive | - |
MoNA010982 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M]+ | positive | - |
MoNA010983 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M]+ | positive | - |
MoNA010520 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M]+ | Positive | MS2 |
MoNA010523 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M]+ | Positive | MS2 |
MoNA010521 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M]+ | Positive | MS2 |
MoNA010524 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M]+ | Positive | MS2 |
MoNA010519 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M]+ | Positive | MS2 |
MoNA010522 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M]+ | Positive | MS2 |
MoNA032252 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M]+ | positive | MS2 |
MoNA036167 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M]+ | positive | MS2 |
MoNA032255 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M]+ | positive | MS2 |
MoNA036166 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M]+ | positive | MS2 |
MoNA032253 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M]+ | positive | MS2 |
MoNA036169 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M]+ | positive | MS2 |
CCMSLIB00000578033 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
MoNA037221 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M]+ | positive | MS2 |
MoNA038602 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M]+ | positive | MS2 |
MoNA016621 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M]+ | positive | - |
HMDB0000097_ms_ms_150 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000097_ms_ms_151 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000097_ms_ms_152 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
BAF_UVA_POS000845 | XEVO-G2S | - | - | - | - | - | - |