MoNA MS database records for Anserine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA017700 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA017701 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
MoNA017702 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M-H]- | negative | MS2 |
MoNA017703 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M-H]- | negative | MS2 |
PM001004 | API 2000 | QqQ | ESI | -18 | [M-H]- | negative | MS2 |
PM000965 | API 2000 | QqQ | ESI | 35 | [M+H]+ | positive | MS2 |
PT209860 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT109860 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
MoNA024039 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA023986 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
PS098607 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS098601 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS098602 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS098603 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS098604 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PR100845 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR100392 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
MoNA010126 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010129 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
MoNA010127 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010130 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
MoNA010125 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
MoNA010128 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
KO000228 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO000229 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO000230 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
KO000231 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO000232 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
KO002328 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO002329 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO002330 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO002331 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO002332 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
KO008819 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.75 | [M+H]+ | positive | MS2 |
KO008820 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.75/0.75 | [M+H]+ | positive | MS3 |
KO008821 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.85/0.55 | [M+H]+ | positive | MS3 |
KO008822 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.85/0.55 | [M+H]+ | positive | MS3 |
KO008823 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.75/0.60/0.65 | [M+H]+ | positive | MS4 |
CCMSLIB00005464483 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005464329 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
FiehnHILIC002594 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FiehnHILIC001768 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC001069 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC000195 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA016939 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
HMDB0000194_ms_ms_313 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000194_ms_ms_314 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000194_ms_ms_315 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
BAF_UVA_POS000609 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000610 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000611 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000612 | XEVO-G2S | - | - | - | - | - | - |