MoNA MS database records for 4-Hydroxybenzoic acid

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
PM004308EsquireQITESI-[M-H]-negativeMS2
ML001751LTQ Orbitrap Velos Thermo Scie...LC-ESI-ITFTESI50 % (nominal)[M-H]-negativeMS2
RP011901maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI10[M+H]+positiveMS2
RP011902maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI20[M+H]+positiveMS2
RP011903maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI40[M+H]+positiveMS2
LU084851Q Exactive Orbitrap (Thermo Sc...LC-ESI-QFTESI15[M-H]-negativeMS2
LU084852Q Exactive Orbitrap (Thermo Sc...LC-ESI-QFTESI30[M-H]-negativeMS2
LU084853Q Exactive Orbitrap (Thermo Sc...LC-ESI-QFTESI45[M-H]-negativeMS2
LU084854Q Exactive Orbitrap (Thermo Sc...LC-ESI-QFTESI60[M-H]-negativeMS2
LU084855Q Exactive Orbitrap (Thermo Sc...LC-ESI-QFTESI75[M-H]-negativeMS2
LU084856Q Exactive Orbitrap (Thermo Sc...LC-ESI-QFTESI90[M-H]-negativeMS2
PT203210Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M-H]-negativeMS2
PT103210Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M+H]+positiveMS2
PT110400Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M+H]+positiveMS2
MoNA023905Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M-H]-negativeMS2
PS032107TQD, WatersFlow-injection QqQ/MSESI10[M-H]-negativeMS2
PS104007TQD, WatersFlow-injection QqQ/MSESI10[M-H]-negativeMS2
PS032108TQD, WatersFlow-injection QqQ/MSESI20[M-H]-negativeMS2
PS104008TQD, WatersFlow-injection QqQ/MSESI20[M-H]-negativeMS2
PR100596UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR100187UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
PR100417UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
MoNA034318Agilent qTOF 6545LC-ESI-QTOF-10 eV[M-H]-negativeMS2
MoNA035643Agilent qTOF 6545LC-ESI-QTOF-10 eV[M-H]-negativeMS2
MoNA034317Agilent qTOF 6545LC-ESI-QTOF-20 eV[M-H]-negativeMS2
MoNA035645Agilent qTOF 6545LC-ESI-QTOF-20 eV[M-H]-negativeMS2
MoNA034316Agilent qTOF 6545LC-ESI-QTOF-40 eV[M-H]-negativeMS2
MoNA035644Agilent qTOF 6545LC-ESI-QTOF-40 eV[M-H]-negativeMS2
MoNA032326Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA033527Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA032324Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA033531Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA032325Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
MoNA033528Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
KO000963API3000, Applied BiosystemsLC-ESI-QQ-10 V[M-H]-negativeMS2
KO000964API3000, Applied BiosystemsLC-ESI-QQ-20 V[M-H]-negativeMS2
KO000965API3000, Applied BiosystemsLC-ESI-QQ-30 V[M-H]-negativeMS2
KO000966API3000, Applied BiosystemsLC-ESI-QQ-40 V[M-H]-negativeMS2
KO000967API3000, Applied BiosystemsLC-ESI-QQ-50 V[M-H]-negativeMS2
GLS00140GCMS-2010 Plus, ShimadzuEI-B---positiveMS1
JP008414HITACHI M-60EI-B--[M]+*positiveMS1
JP003521HITACHI M-68EI-B--[M]+*positiveMS1
JP009473HITACHI M-80EI-B--[M]+*positiveMS1
JP010315HITACHI M-80AEI-B--[M]+*positiveMS1
JP010824JEOL JMS-D-3000EI-B--[M]+*positiveMS1
FiehnLib000313Leco Pegasus IVGC-EI-TOF---positiveMS1
CCMSLIB00005464059Orbitrap---[M-H]-negativeMS2
NUTRI-METAB-FEM-NEG000087Orbitrap---M-Hnegative-
MoNA042372Orbitrap---M+Hpositive-
MoNA042373Orbitrap---M+Hpositive-
KZ000178Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
OUF00425Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
PR010226Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
CCMSLIB00000578301Q-Exactive Plus---[M-H]-negativeMS2
CCMSLIB00005720793qTof---[M-H]-negativeMS2
CCMSLIB00000078846qTof---[M+H]+positiveMS2
CCMSLIB00005720500qTof---[M+H]+positiveMS2
FiehnHILIC000989Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
MoNA037974Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
MoNA038400Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
MoNA037250Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA037665Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
EMBL-MCF_spec68623Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M-H]-negativeMS2
MoNA016638XEVO-G2SLC-ESI-QTOF-6V (MS1); Ramp 15V-30V (MSE)[M+H]+positive-
HMDB0000500_ms_ms_716XEVO-G2SQuattro_QQQ---negative-
HMDB0000500_ms_ms_717XEVO-G2SQuattro_QQQ---negative-
HMDB0000500_ms_ms_718XEVO-G2SQuattro_QQQ---negative-
HMDB0000500_c_ms_1306XEVO-G2SGC-MS-----
HMDB0000500_ei_ms_1592XEVO-G2S------
  logo