Summary of Study ST002335
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001498. The data can be accessed directly via it's Project DOI: 10.21228/M83D9C This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002335 |
Study Title | Pathogenic Auxilin mutations affect lipids that are critical to Synaptojanin function |
Study Summary | Mass spectrometry was performed on heads of 15DO flies homogenized in 100 µl D-PBS (Dulbecco’s phosphate-buffered saline without Mg2+ and Ca2+) by Lipotype. Fifteen fly heads were pooled from three independent crosses for each analysis, and mass spectrometry was performed on n=7 for wild-type, n≥4 analyses for dAuxWT/WT, dAuxRG/RG, dAuxWT/F956x and dAuxRG/F956x and n=3 for dAuxWT/F956x and dAuxRG/F956x overexpressing Synj. |
Institute | VIB-KU Leuven |
Last Name | Jacquemyn |
First Name | Julie |
Address | Medical Sciences Building 7-25, Edmonton, Alberta, T6H 0L2, Canada |
jacquemynjulie@ualberta.ca | |
Phone | +1 (587) 3409325 |
Submit Date | 2022-10-27 |
Analysis Type Detail | LC-MS |
Release Date | 2022-11-21 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003814 |
---|---|
Analysis type | MS |
Chromatography type | None (Direct infusion) |
Chromatography system | none |
Column | none |
MS Type | ESI |
MS instrument type | QTRAP |
MS instrument name | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE |
Units | pMol |
MS:
MS ID: | MS003556 |
Analysis ID: | AN003814 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | QTRAP |
MS Type: | ESI |
MS Comments: | Samples are analyzed in both positive and negative ion modes, with MS resolution Rm/z=200=280000 and MSMS resolution Rm/z=200=17500, in a single acquisition. Acquired data was processed using lipid identification software based on LipidXplorer (1). Data post-processing and normalization were performed by Lipotype using a developed data management system. Data analysis was performed using GraphPad Prism software 9.3.1. Pmol values (obtained by MS) of individual lipid species were transformed into a fraction of the total PA, DAG, PI, PC, PE, and PS lipids in the sample. (1)Herzog, R. et al. Lipidxplorer: A software for consensual cross-platform lipidomics. PLoS ONE 7, e29851 (2012). |
Ion Mode: | POSITIVE |