Summary of Study ST002246
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001434. The data can be accessed directly via it's Project DOI: 10.21228/M8C70Q This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002246 |
Study Title | Longitudinal fecal metabolomic profiles from mothers and their infants in the EDIA study |
Study Summary | In a cohort consisting of 32 mother-infant dyads, we profiled the fecal metabolome at birth and at 3 and 6 months of infant age. Metagenomes from the same samples were also generated. |
Institute | Broad Institute of MIT and Harvard |
Last Name | Xavier |
First Name | Ramnik |
Address | 415 Main Street |
rxavier@broadinstitute.org | |
Phone | 617717084 |
Submit Date | 2022-08-02 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2022-11-23 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003666 | AN003667 | AN003668 | AN003669 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | Reversed phase | HILIC | Reversed phase |
Chromatography system | Shimadzu Nexera X2 | Shimadzu Nexera X2 | Shimadzu Nexera X2 | Shimadzu Nexera X2 |
Column | Waters Atlantis HILIC (150 x 2mm,3um) | Waters Acquity BEH C8 (100 x 2.1mm,1.7um) | Phenomenex Luna NH2 (150 x 2.1mm,3um) | Waters Acquity T3 (150 x 2.1 mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | POSITIVE | NEGATIVE | NEGATIVE |
Units | Unitless Abundances | Unitless Abundances | Unitless Abundances | Unitless Abundances |
MS:
MS ID: | MS003417 |
Analysis ID: | AN003666 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Raw data were processed using TraceFinder 3.3 software (Thermo Fisher Scientific; Waltham, MA) and Progenesis QI (Nonlinear Dynamics; Newcastle upon Tyne, UK). Metabolite identities were confirmed using authentic reference standards or reference samples. |
Ion Mode: | POSITIVE |
MS ID: | MS003418 |
Analysis ID: | AN003667 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Raw data were processed using TraceFinder 3.3 software (Thermo Fisher Scientific; Waltham, MA) and Progenesis QI (Nonlinear Dynamics; Newcastle upon Tyne, UK). Metabolite identities were confirmed using authentic reference standards or reference samples. |
Ion Mode: | POSITIVE |
MS ID: | MS003419 |
Analysis ID: | AN003668 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Raw data were processed using TraceFinder 3.3 software (Thermo Fisher Scientific; Waltham, MA) and Progenesis QI (Nonlinear Dynamics; Newcastle upon Tyne, UK). Metabolite identities were confirmed using authentic reference standards or reference samples. |
Ion Mode: | NEGATIVE |
MS ID: | MS003420 |
Analysis ID: | AN003669 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Raw data were processed using TraceFinder 3.3 software (Thermo Fisher Scientific; Waltham, MA) and Progenesis QI (Nonlinear Dynamics; Newcastle upon Tyne, UK). Metabolite identities were confirmed using authentic reference standards or reference samples. |
Ion Mode: | NEGATIVE |