Summary of Study ST001438
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000988. The data can be accessed directly via it's Project DOI: 10.21228/M80680 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001438 |
Study Title | Sub-nanoliter metabolomics via mass spectrometry to characterize volume-limited samples - MSC |
Study Summary | The human metabolome provides a window into the mechanisms and biomarkers of various diseases. However, because of limited availability, many sample types are still difficult to study by metabolomic analyses. Here, we present a new mass spectrometry (MS)-based metabolomics strategy that only consumes sub-nanoliter sample volumes. The approach consists of combining a customized metabolomics workflow with a pulsed MS ion generation method, known as triboelectric nanogenerator inductive nanoelectrospray ionization (TENGi nanoESI) MS. A second example to illustrate TENGi MS capabilities involves rare cell metabolomics of cultured mesenchymal stromal cells (MSCs), a cell type that has shown potential for treating a variety of chronic diseases. Examination of metabolic changes of MSCs cultured under conditions that may impact in vitro therapeutic activity, such as aggregate culture, or preconditioning with interferon gamma (IFN- γ)13, is critical for identifying attributes of cell quality. Reducing cell numbers required to perform MSC metabolomic analysis is essential for improving the manufacturing of highly therapeutic MSCs without significantly impeding production. |
Institute | Georgia Institute of Technology |
Last Name | Fernandez |
First Name | Facundo |
Address | 901 Atlantic Dr NE, Atlanta, GA, 30332, USA |
fernandez@gatech.edu | |
Phone | 404-385-4432 |
Submit Date | 2020-08-02 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | MS(Dir. Inf.) |
Release Date | 2020-09-14 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002402 |
---|---|
Analysis type | MS |
Chromatography type | None (Direct infusion) |
Chromatography system | none |
Column | none |
MS Type | ESI |
MS instrument type | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE |
Units | Normalized Intensity (Intensity ratio against internal standard signal)) |