MB Sample ID: SA332115

Local Sample ID:MXP500L-0-5711_1036867631_19_0_1_1_00_1036866439_16_R30V3
Subject ID:SU003184
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005026 AN005027
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system ExionLC AD chromatography system (AB Sciex, Framingham, MA, USA) ExionLC AD chromatography system (AB Sciex, Framingham, MA, USA)
Column MxP Quant 500 Column System (Biocrates Part No: 21117) MxP Quant 500 Column System (Biocrates Part No: 21117)
MS Type ESI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name ABI Sciex 6500+ QTrap ABI Sciex 6500+ QTrap
Ion Mode NEGATIVE POSITIVE
Units µM µM

MS:

MS ID:MS004765
Analysis ID:AN005026
Instrument Name:ABI Sciex 6500+ QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Measurements were carried out using LC-MS/MS and flow injection (FIA)-MS/MS analyses on a Sciex 6500+ series mass spectrometer coupled to an ExionLC AD chromatography system (AB Sciex, Framingham, MA, USA), utilizing the Analyst 1.7.1 software with hotfix 1 (also AB SCIEX). All required standards, quality controls and eluents were included in the kit, as well as the chromatographic column for the LC-MS/MS analysis part. Preparation of the measurement worklist as well as data validation and evaluation were performed with the software supplied with the kit (MetIDQ-Oxygen-DB110-3005, Biocrates Life Sciences). MS(LC2_neg): Scheduled MRM experiment in negative polarity. Detection window of 30 s, target scan time of 0.15 s and 3 ms pause between mass ranges. Q1 and Q3 were held at unit resolution. Source parameters were as follows: CUR 35, CAD 8, voltage –4.5 kV, temperature 650 °C, ion source gas at 40 and 40.
Ion Mode:NEGATIVE
  
MS ID:MS004766
Analysis ID:AN005027
Instrument Name:ABI Sciex 6500+ QTrap
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Measurements were carried out using LC-MS/MS and flow injection (FIA)-MS/MS analyses on a Sciex 6500+ series mass spectrometer coupled to an ExionLC AD chromatography system (AB Sciex, Framingham, MA, USA), utilizing the Analyst 1.7.1 software with hotfix 1 (also AB SCIEX). All required standards, quality controls and eluents were included in the kit, as well as the chromatographic column for the LC-MS/MS analysis part. Preparation of the measurement worklist as well as data validation and evaluation were performed with the software supplied with the kit (MetIDQ-Oxygen-DB110-3005, Biocrates Life Sciences). MS(LC1_pos): Scheduled MRM experiment in positive polarity. Detection window of 30 s, target scan time of 0.15 s and 3 ms pause between mass ranges. Q1 and Q3 were held at unit resolution. Source parameters were as follows: CUR 45, CAD 9, voltage 5.5 kV, temperature 500 °C, ion source gas at 60 and 70.
Ion Mode:POSITIVE