Return to study ST002251 main page

MB Sample ID: SA216633

Local Sample ID:FIT01-211-pos
Subject ID:SU002337
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:6-17 years
Weight Or Weight Range:Non-exacerbation-prone IQR: 30-68 kg; Exacerbation-prone IQR: 42-63 kg
Height Or Height Range:Non-exacerbation-prone IQR: 131-165 cm; Exacerbation-prone IQR: 140-163 cm
Gender:Male and female
Human Race:18 white, 189 Black, 7 more than one race, 1 Asian
Human Ethnicity:2 Hispanic, 113 Not Hispanic
Human Medications:92 on high-dose inhaled corticosteroids; 94 on long-acting beta adrenergic receptor agonists; 111 on Montelukast
Human Smoking Status:24 exposed to tobacco smoke
Human Inclusion Criteria:1) current or historical evidence of >=12% reversibility in forced expiratory volume in one second (FEV1) relative to baseline after bronchodilator administration; 2) airway hyperresponsiveness to methacholine, with a provocative concentration of methacholine causing a 20% drop in FEV1
Human Exclusion Criteria:1) premature birth before 35 weeks of gestation; 2) other chronic airway disorders that could mimic asthma.

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003677 AN003678
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Vanquish Horizon Binary ultrahigh performance liquid chromatography system Vanquish Horizon Binary ultrahigh performance liquid chromatography system
Column SeQuant ZIC-HILIC SeQuant ZIC-HILIC
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

MS:

MS ID:MS003428
Analysis ID:AN003677
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were processed using Compound Discoverer 3.2 (Thermo). Minimum peak intensity was 5E5 for positive mode. Retention times were aligned across runs, quality control (QC) pooled sample areas were normalized per metabolite using a cubic spline method, requiring <50% relative standard deviation after correction for compound retention. Missing values were gap-filled based on real peak detection and metabolites with max sample area <5-fold that of the blank were censored.
Ion Mode:POSITIVE
Capillary Temperature:275
Ion Spray Voltage:+3.5 kV
Automatic Gain Control:1E6
  
MS ID:MS003429
Analysis ID:AN003678
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were processed using Compound Discoverer 3.2 (Thermo). Minimum peak intensity was 2E5 for negative mode. Retention times were aligned across runs, quality control (QC) pooled sample areas were normalized per metabolite using a cubic spline method, requiring <50% relative standard deviation after correction for compound retention. Missing values were gap-filled based on real peak detection and metabolites with max sample area <5-fold that of the blank were censored.
Ion Mode:NEGATIVE
Capillary Temperature:275
Ion Spray Voltage:-2.75 kV
Automatic Gain Control:1E6