Combined analysis:
Analysis ID | AN003670 | AN003671 | AN003672 | AN003673 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | Reversed phase | HILIC | Reversed phase |
Chromatography system | Shimadzu Nexera X2 | Shimadzu Nexera X2 | Shimadzu Nexera X2 | Shimadzu Nexera X2 |
Column | Waters Atlantis HILIC (150 x 2mm,3um) | Waters Acquity BEH C8 (100 x 2.1mm,1.7um) | Phenomenex Luna NH2 (150 x 2.1mm,3um) | Waters Acquity T3 (150 x 2.1 mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | POSITIVE | NEGATIVE | NEGATIVE |
Units | Abundances | Abundances | Unitless Abundances | Abundances |
MS:
MS ID: | MS003421 |
Analysis ID: | AN003670 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Raw data were processed using TraceFinder 3.3 software (Thermo Fisher Scientific; Waltham, MA) and Progenesis QI (Nonlinear Dynamics; Newcastle upon Tyne, UK). Metabolite identities were confirmed using authentic reference standards or reference samples. |
Ion Mode: | POSITIVE |
MS ID: | MS003422 |
Analysis ID: | AN003671 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Raw data were processed using TraceFinder 3.3 software (Thermo Fisher Scientific; Waltham, MA) and Progenesis QI (Nonlinear Dynamics; Newcastle upon Tyne, UK). Metabolite identities were confirmed using authentic reference standards or reference samples. |
Ion Mode: | POSITIVE |
MS ID: | MS003423 |
Analysis ID: | AN003672 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Raw data were processed using TraceFinder 3.3 software (Thermo Fisher Scientific; Waltham, MA) and Progenesis QI (Nonlinear Dynamics; Newcastle upon Tyne, UK). Metabolite identities were confirmed using authentic reference standards or reference samples. |
Ion Mode: | NEGATIVE |
MS ID: | MS003424 |
Analysis ID: | AN003673 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Raw data were processed using TraceFinder 3.3 software (Thermo Fisher Scientific; Waltham, MA) and Progenesis QI (Nonlinear Dynamics; Newcastle upon Tyne, UK). Metabolite identities were confirmed using authentic reference standards or reference samples. |
Ion Mode: | NEGATIVE |