MB Sample ID: SA211844
| Local Sample ID: | AD2 |
| Subject ID: | SU002299 |
| Subject Type: | Human |
| Subject Species: | Homo sapiens |
| Taxonomy ID: | 9606 |
| Age Or Age Range: | 50-90 yrs |
| Species Group: | Mammals |
Select appropriate tab below to view additional metadata details:
Combined analysis:
| Analysis ID | AN003618 | AN003619 | AN003620 | AN003621 |
|---|---|---|---|---|
| Chromatography ID | CH002673 | CH002674 | CH002675 | CH002676 |
| MS ID | MS003369 | MS003370 | MS003371 | MS003372 |
| Analysis type | MS | MS | MS | MS |
| Chromatography type | Reversed phase | Reversed phase | Reversed phase | Reversed phase |
| Chromatography system | Thermo Vanquish | Thermo Vanquish | Thermo Vanquish | Thermo Vanquish |
| Column | Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) | Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) | Phenomenex kinetex C18 (150 x 2.1mm,1.7um) | Phenomenex kinetex C18 (150 x 2.1mm,1.7um) |
| MS Type | ESI | ESI | ESI | ESI |
| MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
| MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
| Ion Mode | NEGATIVE | POSITIVE | NEGATIVE | POSITIVE |
| Units | peak area | peak area | peak area | peak area |
MS:
| MS ID: | MS003369 |
| Analysis ID: | AN003618 |
| Instrument Name: | Thermo Q Exactive Orbitrap |
| Instrument Type: | Orbitrap |
| MS Type: | ESI |
| MS Comments: | Resolution 70,000, scan range 65-900 m/z, maximum injection time 200 ms, microscans 2, automatic gain control (AGC) 3 x 10^6 ions, source voltage 4.0 kV, capillary temperature 320 C, and sheath gas 45, auxiliary gas 15, and sweep gas 0 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database. |
| Ion Mode: | NEGATIVE |
| MS ID: | MS003370 |
| Analysis ID: | AN003619 |
| Instrument Name: | Thermo Q Exactive Orbitrap |
| Instrument Type: | Orbitrap |
| MS Type: | ESI |
| MS Comments: | Resolution 70,000, scan range 65-900 m/z, maximum injection time 200 ms, microscans 2, automatic gain control (AGC) 3 x 10^6 ions, source voltage 4.0 kV, capillary temperature 320 C, and sheath gas 45, auxiliary gas 15, and sweep gas 0 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database. |
| Ion Mode: | POSITIVE |
| MS ID: | MS003371 |
| Analysis ID: | AN003620 |
| Instrument Name: | Thermo Q Exactive Orbitrap |
| Instrument Type: | Orbitrap |
| MS Type: | ESI |
| MS Comments: | Resolution 70,000, scan range 65-900 m/z, maximum injection time 200 ms, microscans 2, automatic gain control (AGC) 3 x 10^6 ions, source voltage 4.0 kV, capillary temperature 320 C, and sheath gas 45, auxiliary gas 15, and sweep gas 0 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database. |
| Ion Mode: | NEGATIVE |
| MS ID: | MS003372 |
| Analysis ID: | AN003621 |
| Instrument Name: | Thermo Q Exactive Orbitrap |
| Instrument Type: | Orbitrap |
| MS Type: | ESI |
| MS Comments: | Resolution 70,000, scan range 65-900 m/z, maximum injection time 200 ms, microscans 2, automatic gain control (AGC) 3 x 10^6 ions, source voltage 4.0 kV, capillary temperature 320 C, and sheath gas 45, auxiliary gas 15, and sweep gas 0 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database. |
| Ion Mode: | POSITIVE |