Analysis ID | AN002993 | AN002994 | AN002995 | AN002996 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | HILIC | Reversed phase | Reversed phase |
Chromatography system | Agilent 1290 Infinity II | Agilent 1290 Infinity II | Agilent 1290 Infinity II | Agilent 1290 Infinity II |
Column | SeQuant ZIC-pHILIC (100 x 2.1mm,5um) | SeQuant ZIC-pHILIC (100 x 2.1mm,5um) | Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um) | Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | QTOF | QTOF | QTOF | QTOF |
MS instrument name | Agilent 6540 QTOF | Agilent 6540 QTOF | Agilent 6545 QTOF | Agilent 6545 QTOF |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | Relative Intensity | Relative Intensity | Relative Intensity | Relative Intensity |
MS:
MS ID: | MS002782 |
Analysis ID: | AN002993 |
Instrument Name: | Agilent 6540 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | gas temperature 200°C, drying gas flow 10 L/min, nebulizer pressure 44 psi, sheath gas temperature 300°C, sheath gas flow 12 L/min, VCap 3000 V, nozzle voltage 2000 V, Fragmentor 100 V, Skimmer 65 V, Oct 1 RF Vpp 750 V, and m/z range 50-1700. Data were acquired under continuous reference mass correction at m/z 121.0509 and 922.0890 for positive ion mode and m/z 119.0363 and 966.0007 for negative ion mode. Polar metabolite identifications were supported by matching the retention time, accurate mass, and MS/MS fragmentation data to our in-house retention time and MS/MS library created from authentic reference standards (Mass Spectrometry Metabolite Library supplied by IROA Technologies, Millipore Sigma, St. Louis, MO, USA) and online MS/MS libraries (Human Metabolome Database (HMDB, https://hmdb.ca), Mass Bank of North America (MoNA, https://mona.fiehnlab.ucdavis.edu/), and mzCloud (https://mzcloud.org). Lipid iterative MS/MS data were annotated with the Agilent Lipid Annotator software. All data files were then analyzed in Skyline (Version 20.1.0.155) to obtain peak areas. m/z values of the metabolite and lipid target lists obtained from the metabolite identification workflow, which had at least an MS/MS match to an online library, were extracted under consideration of retention times. |
Ion Mode: | POSITIVE |
MS ID: | MS002783 |
Analysis ID: | AN002994 |
Instrument Name: | Agilent 6540 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | gas temperature 200°C, drying gas flow 10 L/min, nebulizer pressure 44 psi, sheath gas temperature 300°C, sheath gas flow 12 L/min, VCap 3000 V, nozzle voltage 2000 V, Fragmentor 100 V, Skimmer 65 V, Oct 1 RF Vpp 750 V, and m/z range 50-1700. Data were acquired under continuous reference mass correction at m/z 121.0509 and 922.0890 for positive ion mode and m/z 119.0363 and 966.0007 for negative ion mode. Polar metabolite identifications were supported by matching the retention time, accurate mass, and MS/MS fragmentation data to our in-house retention time and MS/MS library created from authentic reference standards (Mass Spectrometry Metabolite Library supplied by IROA Technologies, Millipore Sigma, St. Louis, MO, USA) and online MS/MS libraries (Human Metabolome Database (HMDB, https://hmdb.ca), Mass Bank of North America (MoNA, https://mona.fiehnlab.ucdavis.edu/), and mzCloud (https://mzcloud.org). Lipid iterative MS/MS data were annotated with the Agilent Lipid Annotator software. All data files were then analyzed in Skyline (Version 20.1.0.155) to obtain peak areas. m/z values of the metabolite and lipid target lists obtained from the metabolite identification workflow, which had at least an MS/MS match to an online library, were extracted under consideration of retention times |
Ion Mode: | NEGATIVE |
MS ID: | MS002784 |
Analysis ID: | AN002995 |
Instrument Name: | Agilent 6545 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Lipids were detected in positive and negative ion mode with the following source parameters: gas temperature 250°C, drying gas flow 11 L/min, nebulizer pressure 35 psi, sheath gas temperature 300°C, sheath gas flow 12 L/min, VCap 3000 V, nozzle voltage 500 V, Fragmentor 160 V, Skimmer 65 V, Oct 1 RF Vpp 750 V, and m/z range 50-1700. Data were acquired under continuous reference mass correction at m/z 121.0509 and 922.0890 in positive ion mode and m/z 119.0363 and 966.0007 in negative ion mode. Polar metabolite identifications were supported by matching the retention time, accurate mass, and MS/MS fragmentation data to our in-house retention time and MS/MS library created from authentic reference standards (Mass Spectrometry Metabolite Library supplied by IROA Technologies, Millipore Sigma, St. Louis, MO, USA) and online MS/MS libraries (Human Metabolome Database (HMDB, https://hmdb.ca), Mass Bank of North America (MoNA, https://mona.fiehnlab.ucdavis.edu/), and mzCloud (https://mzcloud.org). Lipid iterative MS/MS data were annotated with the Agilent Lipid Annotator software. All data files were then analyzed in Skyline (Version 20.1.0.155) to obtain peak areas. m/z values of the metabolite and lipid target lists obtained from the metabolite identification workflow, which had at least an MS/MS match to an online library, were extracted under consideration of retention times |
Ion Mode: | POSITIVE |
MS ID: | MS002785 |
Analysis ID: | AN002996 |
Instrument Name: | Agilent 6545 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Lipids were detected in positive and negative ion mode with the following source parameters: gas temperature 250°C, drying gas flow 11 L/min, nebulizer pressure 35 psi, sheath gas temperature 300°C, sheath gas flow 12 L/min, VCap 3000 V, nozzle voltage 500 V, Fragmentor 160 V, Skimmer 65 V, Oct 1 RF Vpp 750 V, and m/z range 50-1700. Data were acquired under continuous reference mass correction at m/z 121.0509 and 922.0890 in positive ion mode and m/z 119.0363 and 966.0007 in negative ion mode. Polar metabolite identifications were supported by matching the retention time, accurate mass, and MS/MS fragmentation data to our in-house retention time and MS/MS library created from authentic reference standards (Mass Spectrometry Metabolite Library supplied by IROA Technologies, Millipore Sigma, St. Louis, MO, USA) and online MS/MS libraries (Human Metabolome Database (HMDB, https://hmdb.ca), Mass Bank of North America (MoNA, https://mona.fiehnlab.ucdavis.edu/), and mzCloud (https://mzcloud.org). Lipid iterative MS/MS data were annotated with the Agilent Lipid Annotator software. All data files were then analyzed in Skyline (Version 20.1.0.155) to obtain peak areas. m/z values of the metabolite and lipid target lists obtained from the metabolite identification workflow, which had at least an MS/MS match to an online library, were extracted under consideration of retention times |
Ion Mode: | NEGATIVE |