Return to study ST002834 main page

MB Sample ID: SA307068

Local Sample ID:Pos_QC5
Subject ID:SU002943
Subject Type:Bacteria
Subject Species:Bacteroides thetaiotaomicron
Taxonomy ID:818
Subject Comments:Fecal derived communities and isolates, supernatant was assayed
Species Group:Bacteria

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004629 AN004630
Chromatography ID CH003483 CH003483
MS ID MS004375 MS004376
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Agilent Zorbax SB-C18 (100 x 3.0 mm, 1.8 um) Agilent Zorbax SB-C18 (100 x 3.0 mm, 1.8 um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units counts, height counts, height

Chromatography:

Chromatography ID:CH003483
Chromatography Summary:Bacterial supernatant were analyzed via reversed phase (C18) coupled to a Thermo Q-Exactive HF high resolution mass spectrometer. Prepared samples were injected onto an Agilent Zorbax SB-C18 column (100 mm length × 3 mm id; 1.8 μm particle size) with an additional Phenomenex KrudKatcher pre-column (2 μm depth x 0.004in ID) maintained at 40°C coupled to an Thermo Vanquish UPLC. The mobile phases were prepared with 0.1% formic acid in either 100% LC-MS grade water for mobile phase (A), 100% water or mobile phase (B), 100% acetonitrile. Gradient elution was performed as follows 3% (B) maintained 0–0.43 min to 97% (B) at 9 min, maintained until 11 min, returning to initial conditions at 11.5 min and equilibrating until the end of the run at 14 min. Flow rate is maintained at 0.4 mL/min. Each sample was analyzed in both positive and negative ionization modes (ESI+, ESI-) via subsequent injections. Full MS-ddMS2 data was collected, an inclusion list was used to prioritize MS2 selection of metabolites from our in-house ‘local’ library, when additional scan bandwidth was available MS2 was collected in a data-dependent manner. Mass range was 60-900 mz, resolution was 60k (MS1) and 15k (MS2), centroid data was collected, loop count was 4, isolation window was 1.5 Da. Metabolomics data was processed using MS-DIAL v4.60 (https://www.nature.com/articles/s41587-020-0531-2) and queried against a combination of our in-house MS2 library and MassBank of North America, the largest freely available spectral repository (https://doi.org/10.1002/mas.21535). Features were excluded from analysis if peak height was not at least 5-fold greater in one or more samples compared to the procedural blank average.
Instrument Name:Thermo Vanquish
Column Name:Agilent Zorbax SB-C18 (100 x 3.0 mm, 1.8 um)
Column Temperature:40C
Flow Gradient:Gradient elution was performed from 100% (B) at 0–2 min to 70% (B) at 7.7 min, 40% (B) at 9.5 min, 30% (B) at 10.25 min, 100% (B) at 12.75 min, isocratic until 16.75 min with a column flow ofGradient elution was performed as follows 3% (B) maintained 0–0.43 min to 97% (B) at 9 min, maintained until 11 min, returning to initial conditions at 11.5 min and equilibrating until the end of the run at 14 min.
Flow Rate:0.4 mL/min.
Solvent A:Water + 0.1% formic acid
Solvent B:Acetonitrile + 0.1% formic acid
Chromatography Type:Reversed phase
  logo