Return to study ST002446 main page

MB Sample ID: SA244714

Local Sample ID:Norm. Area: 088_0003_02E_R_A07xWTxMx03xconcRPneg_28SEP21_CEL_MOU_LUM_0000_04AC_15MIN_KP_KP_01.raw (F204)
Subject ID:SU002535
Subject Type:Cultured cells
Subject Species:Mus musculus
Taxonomy ID:10090
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002535
Subject Type:Cultured cells
Subject Species:Mus musculus
Taxonomy ID:10090
Gender:Male and female

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
Norm. Area: 088_0003_02E_R_A07xWTxMx03xconcRPneg_28SEP21_CEL_MOU_LUM_0000_04AC_15MIN_KP_KP_01.raw (F204)SA244714FL030677WTGenotype

Collection:

Collection ID:CO002528
Collection Summary:Lin-c-Kit+ cells, a fraction where LSKs reside, were selected four weeks after tet-off and BCR-ABL induction from the BM of miR-142−/−BCR-ABL and miR-142+/+BCR-ABL mice. Lin- cells were firstly selected using Lineage depletion microbeads and c-kit+ cells were then selected using anti-mouse CD117 microbeads (both from Miltenyi Biotec, San Diego, CA).
Sample Type:Cultured cells

Treatment:

Treatment ID:TR002547
Treatment Summary:NA

Sample Preparation:

Sampleprep ID:SP002541
Sampleprep Summary:Metabolites extraction was performed by adding chilled methanol: acetonitrile: water (2:1:1, v/v/v)) to the cell pellet of pooled Lin-c-kit+ cells followed by three freeze-thaw cycles. The lysed cells were precipitated by centrifugation at 15,000 rpm for 10 min at 4 °C and metabolites in the supernatant were vacuum concentrated and subjected to LC-MS analysis.

Combined analysis:

Analysis ID AN003984 AN003985 AN003986 AN003987
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column Thermo Hypersil GOLD C18 (150 x 2.1mm, 1.9um) Thermo Hypersil GOLD C18 (150 x 2.1mm, 1.9um) Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Fusion Tribrid Orbitrap Thermo Fusion Tribrid Orbitrap Thermo Fusion Tribrid Orbitrap Thermo Fusion Tribrid Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units Peak Area Peak Area Peak Area Peak area

Chromatography:

Chromatography ID:CH002946
Instrument Name:Thermo Dionex Ultimate 3000 RS
Column Name:Thermo Hypersil GOLD C18 (150 x 2.1mm, 1.9um)
Column Temperature:40
Flow Gradient:10 min linear gradient from 100% solvent A and 0% solvent B to 2% solvent A and 98% solvent B, and 5 min of equilibration time
Flow Rate:0.35 mL/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase
  
Chromatography ID:CH002947
Instrument Name:Thermo Dionex Ultimate 3000 RS
Column Name:Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um)
Column Temperature:40
Flow Gradient:99% B for 1 min, 99% to 85% for 2 min, 85% to 75% B for 3 min, 75% to 30% B for 3 min, 30% B for 1 min and 5 min column equilibration at 99% B
Flow Rate:0.4 mL/min
Solvent A:95% water/5% acetonitrile; 10 mM ammonium acetate
Solvent B:95% acetonitrile/5% water; 10 mM ammonium acetate
Chromatography Type:HILIC

MS:

MS ID:MS003718
Analysis ID:AN003984
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS1 data were acquired over a mass range of 70 to 1500 m/z in the orbitrap operated at a resolution of 60,000. MS/MS data were acquired in AcquireX mode using the iterative precursor exclusion workflow, with a stepped HCD collision energy at 20, 35 and 50, at a resolution of 30,000 in the orbitrap
Ion Mode:POSITIVE
  
MS ID:MS003719
Analysis ID:AN003985
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS1 data were acquired over a mass range of 70 to 1500 m/z in the orbitrap operated at a resolution of 60,000. MS/MS data were acquired in AcquireX mode using the iterative precursor exclusion workflow, with a stepped HCD collision energy at 20, 35 and 50, at a resolution of 30,000 in the orbitrap
Ion Mode:NEGATIVE
  
MS ID:MS003720
Analysis ID:AN003986
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS1 data were acquired over a mass range of 70 to 1500 m/z in the orbitrap operated at a resolution of 60,000. MS/MS data were acquired in AcquireX mode using the iterative precursor exclusion workflow, with a stepped HCD collision energy at 20, 35 and 50, at a resolution of 30,000 in the orbitrap
Ion Mode:POSITIVE
  
MS ID:MS003721
Analysis ID:AN003987
Instrument Name:Thermo Fusion Tribrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS1 data were acquired over a mass range of 70 to 1500 m/z in the orbitrap operated at a resolution of 60,000. MS/MS data were acquired in AcquireX mode using the iterative precursor exclusion workflow, with a stepped HCD collision energy at 20, 35 and 50, at a resolution of 30,000 in the orbitrap
Ion Mode:NEGATIVE