Return to study ST002233 main page
MB Sample ID: SA212689
| Local Sample ID: | batch2_MT_20210727_089 |
| Subject ID: | SU002319 |
| Subject Type: | Human |
| Subject Species: | Homo sapiens |
| Taxonomy ID: | 9606 |
| Species Group: | Mammals |
Select appropriate tab below to view additional metadata details:
Subject:
| Subject ID: | SU002319 |
| Subject Type: | Human |
| Subject Species: | Homo sapiens |
| Taxonomy ID: | 9606 |
| Species Group: | Mammals |
Factors:
| Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
|---|---|---|---|---|
| batch2_MT_20210727_089 | SA212689 | FL025966 | CommercialQstdPooled | SampleType |
Collection:
| Collection ID: | CO002312 |
| Collection Summary: | Two different deidentified human plasma pooled samples were used for this study: a) commercial Qstd plasma pool ; b) biosamples (from 1R01AI149746 (NIH-NIAID) samples) plasma pool |
| Sample Type: | Blood (plasma) |
| Storage Conditions: | -80℃ |
Treatment:
| Treatment ID: | TR002331 |
| Treatment Summary: | No treatment |
Sample Preparation:
| Sampleprep ID: | SP002325 |
| Sampleprep Summary: | The plasma samples were thawed in ice. Metabolites extraction were carried out by protein precipitation using extraction solvent, acetonitrile:methanol (8:1, v/v) containing 0.1% formic acid and isotope labelled Trimethyl-13C3]-caffeine, [13C5]-L-glutamic acid, [15N2]-Uracil, [15N,13C5]-L-methionine, [13C6]-D-glucose and [15N]-L-tyrosin as spike-in controls. 30 μl of plasma was taken and 60 μl of extraction solvent was added. All samples were vortexed and incubated with shaking at 1000 rpm for 10 min at 4°C followed by centrifugation at 4°C for 15 min at 15,000 rpm. The supernatant was transferred into mass spec vials and 2 μl injected into UHPLC-MS. |
| Extraction Method: | Protein precipitation |
| Extract Storage: | -80℃ |
Combined analysis:
| Analysis ID | AN003643 |
|---|---|
| Chromatography ID | CH002697 |
| MS ID | MS003394 |
| Analysis type | MS |
| Chromatography type | HILIC |
| Chromatography system | Thermo Scientific Vanquish Horizon UHPLC system |
| Column | HILIC column, AccucoreTM-150-Amide (50 x 2.1mm,2.6um) |
| MS Type | ESI |
| MS instrument type | Orbitrap |
| MS instrument name | Thermo Orbitrap ID-X Tribrid |
| Ion Mode | POSITIVE |
| Units | m/z values |
Chromatography:
| Chromatography ID: | CH002697 |
| Chromatography Summary: | Mobile phase: 10 mM ammonium acetate in 95% acetonitrile containing 0.1% acetic acid as mobile phase A and 10 mM ammonium acetate in 50% acetonitrile containing 0.1% acetic acid as mobile phase B were used for HILIC method. Mobile phase gradient: For HILIC acquisition, following gradient was applied at a flow rate of 0.55 ml/min: 0-0.1 min: 0% B, 0.10-5.0 min: 98% B, 5.00-5.50 min: 0% B and 4.5 min for cleaning and equilibration of column.For RP column, following gradient was applied at a flow rate of 0.4 ml/min: 0-0.1 min: 0% B, 0.10-1.9 min: 60% B, 1.9-5.0 min: 98% B, 5.00-5.10 min: 0% B and 4.9 min cleaning and column equilibration. |
| Instrument Name: | Thermo Scientific Vanquish Horizon UHPLC system |
| Column Name: | HILIC column, AccucoreTM-150-Amide (50 x 2.1mm,2.6um) |
| Column Temperature: | 45 |
| Flow Gradient: | 0-0.1 min: 0% B, 0.10-5.0 min: 98% B, 5.00-5.50 min: 0% B and 4.5 min for cleaning and equilibration of column. |
| Flow Rate: | 0.55 ml/min |
| Solvent A: | 95% acetonitrile/5% water; 0.1% acetic acid; 10 mM ammonium acetate |
| Solvent B: | 50% acetonitrile/50% water; 0.1% acetic acid; 10 mM ammonium acetate |
| Chromatography Type: | HILIC |
MS:
| MS ID: | MS003394 |
| Analysis ID: | AN003643 |
| Instrument Name: | Thermo Orbitrap ID-X Tribrid |
| Instrument Type: | Orbitrap |
| MS Type: | ESI |
| MS Comments: | None |
| Ion Mode: | POSITIVE |