Return to study ST002044 main page

MB Sample ID: SA192285

Local Sample ID:NHF-27
Subject ID:SU002126
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002126
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
NHF-27SA192285FL023603NAGender

Collection:

Collection ID:CO002119
Collection Summary:Serum samples were collected from CVD patients at the Safdarjung Hospital, New Delhi. In all assessments, all individuals were asked to provide complete information regarding personal health history, self-rated health, and family history of diabetes, tobacco use, and physical activity. Ethical approval was obtained at Safdarjung Hospital, New Delhi for sample collection.
Sample Type:Blood (serum)

Treatment:

Treatment ID:TR002138
Treatment Summary:NA

Sample Preparation:

Sampleprep ID:SP002132
Sampleprep Summary:Serum samples (100µl) should be properly thawed and spin at 5K rpm for one minute, added with 100 % MeOH (300µl, in1:3 ratio) and vortex well (30s), incubated on ice for 10 minutes and then centrifuged at 10K rpm for 10 minutes at 4℃. Equally, transfer the supernatant into two different well-labeled tubes and then speed vacuum dry and stored at -80℃. One set of the tubes is used for the analysis of polar metabolites and the other one is used for the non-polar metabolites. For the reconstitution of polar metabolites, 50% ACN (50 µl) is added into the vacuum dried sample and for nonpolar 15% of MeOH (50 µl) is used. After the addition of reconstitutes, vortex well for 10 min and centrifuged at 10K rpm for 10 minutes at 4℃ and transfer the supernatant (approx. 40-45 µl) into MS vials. Remove 10µl form every sample containing MS vials and pooled together into a 15 ml tube to use as QC. Then, the samples were stored at -80℃ for further analysis.

Combined analysis:

Analysis ID AN003325 AN003326 AN003327 AN003328
Analysis type MS MS MS MS
Chromatography type HILIC HILIC Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters Xbridge BEH HILIC (75 x 2.1mm,2.5um) Waters Xbridge BEH HILIC (75 x 2.1mm,2.5um) Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Fusion Orbitrap Thermo Fusion Orbitrap Thermo Fusion Orbitrap Thermo Fusion Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units peak height peak height peak height peak height

Chromatography:

Chromatography ID:CH002464
Chromatography Summary:For hydrophilic interaction (HILIC) chromatography, 5 µl of the prepared samples were injected for analysis. An ultimate 3000 UPLC XBridge BHE Amide column (2.1 x 100 mm, 2.5 µm; Waters Corporation) was used and maintained at 35℃ for separation. The mobile phase was delivered at 0.35mL/min. The mobile phase A consisted of 20mM ammonium acetate in the water of pH 9.0 and mobile phase B was 100% acetonitrile. The elution gradient is used as follows: 0 min-85% B, 2 min-10% B, 14 min- 10% B, 14.1 min- 85% B, 16 min- 85%B.
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Waters Xbridge BEH HILIC (75 x 2.1mm,2.5um)
Column Temperature:35
Flow Gradient:0 min-85% B, 2 min-10% B, 14 min- 10% B, 14.1 min- 85% B, 16 min- 85%B.
Flow Rate:0.35mL/min
Solvent A:100% water; 20 mM ammonium acetate, pH 9.0
Solvent B:100% acetonitrile
Chromatography Type:HILIC
  
Chromatography ID:CH002465
Chromatography Summary:For reversed-phase (RP) chromatographic analyses, 5 µL of prepared samples were injected. The separation was performed using a UPLC ultimate 3000 using the HSS T3 column (2.1x 100mm, 1.7 µm; Waters Corporation) at 40℃. The mobile phase was delivered at 300µL/min and consisted of eluent A (water with 0.1%formic acid) and eluent B (acetonitrile with 0.1% formic acid), delivered in a gradient profile: 0min-1% B, 1min-15%B, 4min-35% B, 7min-95% B, 9 min- 95% B, 10min-1% B, 14 min- 1% B.
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um)
Flow Gradient:0min-1% B, 1min-15%B, 4min-35% B, 7min-95% B, 9 min- 95% B, 10min-1% B, 14 min- 1% B
Flow Rate:300µL/min
Solvent A:100% water; 0.1%formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS003095
Analysis ID:AN003325
Instrument Name:Thermo Fusion Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The electrospray ionization (ESI) source was operated for both positive mode (+) and negative (-) ionization at 120,000 resolution in MS1 mode and 30000 resolution in data-dependent MS2 scan mode. The spray voltage used for these positive and negative modes is 4000 and 35000 volts respectively. Sheath gas and auxiliary gas were set to 42 and 11 respectively. The mass scan range was 60-900 m/z, ACG (Automatic control gain) target at 100000 ions and maximum injection time was 50 ms for MS and ACG target was 20000 ions and maximum injection time 60 ms for MSMS was used. Data were processed using the IDSL.IPA software (https://cran.r-project.org/web/packages/IDSL.IPA/index.html)
Ion Mode:POSITIVE
  
MS ID:MS003096
Analysis ID:AN003326
Instrument Name:Thermo Fusion Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The electrospray ionization (ESI) source was operated for both positive mode (+) and negative (-) ionization at 120,000 resolution in MS1 mode and 30000 resolution in data-dependent MS2 scan mode. The spray voltage used for these positive and negative modes is 4000 and 35000 volts respectively. Sheath gas and auxiliary gas were set to 42 and 11 respectively. The mass scan range was 60-900 m/z, ACG (Automatic control gain) target at 100000 ions and maximum injection time was 50 ms for MS and ACG target was 20000 ions and maximum injection time 60 ms for MSMS was used. Data were processed using the IDSL.IPA software (https://cran.r-project.org/web/packages/IDSL.IPA/index.html)
Ion Mode:NEGATIVE
  
MS ID:MS003097
Analysis ID:AN003327
Instrument Name:Thermo Fusion Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The electrospray ionization (ESI) source was operated for both positive mode (+) and negative (-) ionization at 120,000 resolution in MS1 mode and 30000 resolution in data-dependent MS2 scan mode. The spray voltage used for these positive and negative modes is 4000 and 35000 volts respectively. Sheath gas and auxiliary gas were set to 42 and 11 respectively. The mass scan range was 60-900 m/z, ACG (Automatic control gain) target at 100000 ions and maximum injection time was 50 ms for MS and ACG target was 20000 ions and maximum injection time 60 ms for MSMS was used. Data were processed using the IDSL.IPA software (https://cran.r-project.org/web/packages/IDSL.IPA/index.html)
Ion Mode:POSITIVE
  
MS ID:MS003098
Analysis ID:AN003328
Instrument Name:Thermo Fusion Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The electrospray ionization (ESI) source was operated for both positive mode (+) and negative (-) ionization at 120,000 resolution in MS1 mode and 30000 resolution in data-dependent MS2 scan mode. The spray voltage used for these positive and negative modes is 4000 and 35000 volts respectively. Sheath gas and auxiliary gas were set to 42 and 11 respectively. The mass scan range was 60-900 m/z, ACG (Automatic control gain) target at 100000 ions and maximum injection time was 50 ms for MS and ACG target was 20000 ions and maximum injection time 60 ms for MSMS was used. Data were processed using the IDSL.IPA software (https://cran.r-project.org/web/packages/IDSL.IPA/index.html)
Ion Mode:NEGATIVE
  logo