Return to study ST001937 main page

MB Sample ID: SA182595

Local Sample ID:SZ92
Subject ID:SU002015
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Mammals

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002015
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Mammals

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
SZ92SA182595FL022304Maligant SPNSPheotypes

Collection:

Collection ID:CO002008
Collection Summary:A total of 1160 plasma samples was obtained from healthy volunteers (n=280), benign SPNs (n=157, center 1=42; center 2=23; center 3=45; center 4=13; center 5=34) and malignant SPNs (stage I, n=723, center 1=118; center 2=105; center 3=139; center 4=33; center 5=328) patients enrolled from 5 independent centers.
Sample Type:Blood (plasma)

Treatment:

Treatment ID:TR002027
Treatment Summary:Without treatment

Sample Preparation:

Sampleprep ID:SP002021
Sampleprep Summary:To undertake comprehensive lipidomic profiling, a sample preparation approach for serum based on liquid-liquid MTBE extraction was utilized to cover diverse classes of lipids. Untargeted lipidomic analysis was performed using a Dionex UltiMate 3000 UHPLC system (Santa Clara, CA, USA) linked online via electrospray ionization source (ESI) with a Q ExactiveTM Hybrid Quadrupole-OrbitrapTM Mass Spectrometer (Thermo Fisher Scientific, Inc., MA, USA). Comprehensive metabolomic analysis was performed on a TRACE 1310 gas chromatograph equipped with an AS 1310 autosampler connected to a TSQ 8000 triple quadrupole mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) as described previously 14.
Sampleprep Protocol ID:346 Lipidomics_LCMSProtocol.pdf

Combined analysis:

Analysis ID AN003150
Analysis type MS
Chromatography type Unspecified
Chromatography system Thermo Trace 1310/Dionex UltiMate 3000 UHPLC
Column TG-5MS
MS Type EI/ESI
MS instrument type Triple quadrupole/Orbitrap
MS instrument name Thermo TSQ 8000/Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units peak height

Chromatography:

Chromatography ID:CH002330
Instrument Name:Thermo Trace 1310/Dionex UltiMate 3000 UHPLC
Column Name:TG-5MS
Chromatography Type:Unspecified

MS:

MS ID:MS002930
Analysis ID:AN003150
Instrument Name:Thermo TSQ 8000/Thermo Q Exactive Orbitrap
Instrument Type:Triple quadrupole/Orbitrap
MS Type:EI/ESI
MS Comments:The raw data files from LC-MS were converted into Analysis Base File (ABF) format by Abf Converter (http://www.reifycs.com/AbfConverter). Then, using the open-source program MS-Dial v.4.24 15, the automatic peak selecting, integration, retention time adjustment by the aforementioned database, and alignment were performed. The retention time index (RI) tolerance in GC-MS was 3,000, while the peak height threshold was 10,000. In LC-MS, the peak height threshold was 1,000,000 in positive ion mode and 500,000 in negative ion mode. The resultant output data table of high quality time-aligned investigated metabolites, together with their related RT, m/z, and peak height acquired for each sample, was statistically analyzed. All metabolite identifications were manually double-checked.
Ion Mode:POSITIVE
  logo