Return to study ST001937 main page
MB Sample ID: SA182595
Local Sample ID: | SZ92 |
Subject ID: | SU002015 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Species Group: | Mammals |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU002015 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Species Group: | Mammals |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
SZ92 | SA182595 | FL022304 | Maligant SPNS | Pheotypes |
Collection:
Collection ID: | CO002008 |
Collection Summary: | A total of 1160 plasma samples was obtained from healthy volunteers (n=280), benign SPNs (n=157, center 1=42; center 2=23; center 3=45; center 4=13; center 5=34) and malignant SPNs (stage I, n=723, center 1=118; center 2=105; center 3=139; center 4=33; center 5=328) patients enrolled from 5 independent centers. |
Sample Type: | Blood (plasma) |
Treatment:
Treatment ID: | TR002027 |
Treatment Summary: | Without treatment |
Sample Preparation:
Sampleprep ID: | SP002021 |
Sampleprep Summary: | To undertake comprehensive lipidomic profiling, a sample preparation approach for serum based on liquid-liquid MTBE extraction was utilized to cover diverse classes of lipids. Untargeted lipidomic analysis was performed using a Dionex UltiMate 3000 UHPLC system (Santa Clara, CA, USA) linked online via electrospray ionization source (ESI) with a Q ExactiveTM Hybrid Quadrupole-OrbitrapTM Mass Spectrometer (Thermo Fisher Scientific, Inc., MA, USA). Comprehensive metabolomic analysis was performed on a TRACE 1310 gas chromatograph equipped with an AS 1310 autosampler connected to a TSQ 8000 triple quadrupole mass spectrometer (Thermo Fisher Scientific, Waltham, MA, USA) as described previously 14. |
Sampleprep Protocol ID: | 346 Lipidomics_LCMSProtocol.pdf |
Combined analysis:
Analysis ID | AN003150 |
---|---|
Analysis type | MS |
Chromatography type | Unspecified |
Chromatography system | Thermo Trace 1310/Dionex UltiMate 3000 UHPLC |
Column | TG-5MS |
MS Type | EI/ESI |
MS instrument type | Triple quadrupole/Orbitrap |
MS instrument name | Thermo TSQ 8000/Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE |
Units | peak height |
Chromatography:
Chromatography ID: | CH002330 |
Instrument Name: | Thermo Trace 1310/Dionex UltiMate 3000 UHPLC |
Column Name: | TG-5MS |
Chromatography Type: | Unspecified |
MS:
MS ID: | MS002930 |
Analysis ID: | AN003150 |
Instrument Name: | Thermo TSQ 8000/Thermo Q Exactive Orbitrap |
Instrument Type: | Triple quadrupole/Orbitrap |
MS Type: | EI/ESI |
MS Comments: | The raw data files from LC-MS were converted into Analysis Base File (ABF) format by Abf Converter (http://www.reifycs.com/AbfConverter). Then, using the open-source program MS-Dial v.4.24 15, the automatic peak selecting, integration, retention time adjustment by the aforementioned database, and alignment were performed. The retention time index (RI) tolerance in GC-MS was 3,000, while the peak height threshold was 10,000. In LC-MS, the peak height threshold was 1,000,000 in positive ion mode and 500,000 in negative ion mode. The resultant output data table of high quality time-aligned investigated metabolites, together with their related RT, m/z, and peak height acquired for each sample, was statistically analyzed. All metabolite identifications were manually double-checked. |
Ion Mode: | POSITIVE |