Return to study ST000317 main page
MB Sample ID: SA014471
Local Sample ID: | SA014 |
Subject ID: | SU000337 |
Subject Type: | Bacterial cells |
Subject Species: | Bacteria |
Species Group: | Bacteria |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU000337 |
Subject Type: | Bacterial cells |
Subject Species: | Bacteria |
Species Group: | Bacteria |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
SA014 | SA014471 | FL003282 | A | Media type |
Collection:
Collection ID: | CO000331 |
Collection Summary: | - |
Sample Type: | Spent culture supernatant |
Treatment:
Treatment ID: | TR000351 |
Treatment Summary: | There are 2 treatments. Each sample is a supernatant from a different bacterial strain grown in culture.There are a total of 17 strains, 10 of which are grown in one type of medium and 7 are grown in another type of medium. Supernatants from the 2 types of media are also submitted for analysis. |
Treatment Protocol Filename: | StudyDesign_NadirMahmood_072914.pdf |
Sample Preparation:
Sampleprep ID: | SP000345 |
Sampleprep Summary: | 1. After quenching the cells add 1 X 106 dried cells to 1.5 ml eppendorff tube. 2. Place the eppendorf tube with cells on dry ice for 20 minutes or til the cells are completely frozen and ice for 20 minutes, till they are completely thawed. Repeat this step twice. 3. Add 1ml of extraction solvent which has been pre-chilled using the ThermoElectron Neslab RTE 740 cooling bath set to -20°C. to the ependorff tube with cells. 4. Repeat step 2 twice with the extraction solvent. 5. Vortex the sample for 10s and shake for 5min at 4°C using the Orbital Mixing Chilling/Heating plate. Centrifuge samples for 2min at 14000 rcf using the centrifuge Eppendorf 5415 D. 6. Aliquot two 500µL portions of the supernatant. One for analysis and one for backup. Store one aliquot in the -20°C freezer as a backup. 7. Evaporate one 500µL aliquot of the sample in the Labconco Centrivap cold trap concentrator to complete dryness. 8. Submit to derivatization. |
Sampleprep Protocol Filename: | SOP_Extraction_of_Cell_pellets.pdf |
Combined analysis:
Analysis ID | AN000503 | AN000504 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Unspecified | Unspecified |
Column | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | Agilent 6530 QTOF | Agilent 6550 QTOF |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak height | Peak height |
Chromatography:
Chromatography ID: | CH000355 |
Chromatography Summary: | UPLC |
Methods Filename: | Data_Dictionary_Fiehn_laboratory_CSH_QTOF_lipidomics_05-29-2014.pdf |
Instrument Name: | Unspecified |
Column Name: | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) |
Column Pressure: | 450-850 bar |
Column Temperature: | 65 C |
Flow Gradient: | 15% B to 99% B |
Flow Rate: | 0.6 mL/min |
Internal Standard: | See data dictionary |
Retention Time: | See data dictionary |
Sample Injection: | 1.67 uL |
Solvent A: | 60% acetonitrile/40% water; 10mM formic acid; 10mM ammonium formate |
Solvent B: | 90% isopropanol/10% acetonitrile; 10mM formic acid; 10mM ammonium formate |
Analytical Time: | 13 min |
Capillary Voltage: | 3500 |
Time Program: | 15 min |
Weak Wash Solvent Name: | Isopropanol |
Weak Wash Volume: | 5 seconds |
Strong Wash Solvent Name: | Isopropanol |
Target Sample Temperature: | Autosampler temp 4 C |
Randomization Order: | Excel |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS000439 |
Analysis ID: | AN000503 |
Instrument Name: | Agilent 6530 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
Ion Mode: | POSITIVE |
Capillary Voltage: | 3500 |
Collision Gas: | Nitrogen |
Dry Gas Flow: | 8 l/min |
Dry Gas Temp: | 325 |
Fragment Voltage: | 120 |
Fragmentation Method: | Auto MS/MS |
Ion Source Temperature: | 325 |
Ion Spray Voltage: | 1000 |
Ionization: | Pos |
Precursor Type: | Intact Molecule |
Reagent Gas: | Nitrogen |
Source Temperature: | 325 C |
Desolvation Gas Flow: | 11 l/min |
Desolvation Temperature: | 350 C |
Nebulizer: | 35 psig |
Octpole Voltage: | 750 |
Resolution Setting: | Extended Dynamic Range |
Scan Range Moverz: | 60-1700 Da |
Scanning Cycle: | 2 Hz |
Scanning Range: | 60-1700 Da |
Skimmer Voltage: | 65 |
MS ID: | MS000440 |
Analysis ID: | AN000504 |
Instrument Name: | Agilent 6550 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
Ion Mode: | NEGATIVE |
Capillary Voltage: | 3500 |
Collision Gas: | Nitrogen |
Dry Gas Flow: | 13 l/min |
Dry Gas Temp: | 200 |
Fragment Voltage: | 175 |
Fragmentation Method: | Auto MS/MS |
Ion Source Temperature: | 325 |
Ion Spray Voltage: | 1000 |
Ionization: | Neg |
Precursor Type: | Intact Molecule |
Reagent Gas: | Nitrogen |
Source Temperature: | 325 C |
Desolvation Gas Flow: | 11 l/min |
Desolvation Temperature: | 350 C |
Nebulizer: | 35 psig |
Octpole Voltage: | 750 |
Resolution Setting: | Extended Dynamic Range |
Scan Range Moverz: | 60-1700 Da |
Scanning Cycle: | 2 Hz |
Scanning Range: | 60-1700 Da |
Skimmer Voltage: | 65 |